electric inverter frequency

  electric inverter frequency reference when the multi function inputs jog frequency reference selection f jog command and r jog command are on.the electric inverter frequency reference default value and set value will change when 0 1-0 3 is changed, for example if preset reference 1 is set to 6.00 Hz and 01-03 is changed … Read more

electric inverter torque reference

TORQUE REFERENCE DELAY TIME . the primary delay time constant of  torque command filter is set in unit of    m r s to adjust the electric inverter torque reference  time constant of the primary delay filmier . to adjust the noise of the torque control signal or the responsive nests with the host controller … Read more

frequency speed and voltage of inverter

  set only  to fine adjust v/f for the output range when using flux vector control of frequency speed and voltage of inverter .normally this setting range and factory setting will be cut by 50%  for the inverter of 200v class . to set the constant e 1-0 4 ~e 1-10 when e 1-0 3 =”f” … Read more

motor system

motor system in inverter MOTOR 2 LINE TO LINE RESISTANCE . To set the motor,s line to line resistance in unit of ohm . note: the factory setting depends on the capacity of the inverter . please set the motor,s line to line resistance u v v – w w u  normally you need to … Read more

inverter dc to ac

Finding the Best Inverter Dc to Ac inverter dc to ac Inverter Dc to Ac – Overview Generally, as soon as an inverter is in over-power mode, it simply suggests that it’s going to sacrifice the surplus power. There are not any inverters used inside the computer system. The smallest inverters are somewhat more portable … Read more

inverter panel

PANEL/REMOTE SETTING VALUE 1. OFF:To select frequency command (b1-01) and operation command (b1-02). ON : Set frequency command/operation command by digital operator . To switch the input method between frequency command and operation command . To switch only at the stop of inverter . Once  the function was set digital keyboard operation method selection key … Read more

winner inverter acceleration time setting

Win- va /vc,s deceleration / acceleration time has 4 options , to switch between these time option , please set deceleration / acceleration time option 1 ,2  at multi function input . setting value 7 = acceleration / deceleration time selection 1 . setting value 1 a =  acceleration / deceleration time selection 2 . … Read more

danfoss inverter

  When terminal 14 is used as frequency command  please h3-09 (frequency command (current ) terminal 14 function selection ) to be if otherwise if you use this function fault (o p e 03)  will occur . when h3 -09 (frequency command ( current ) terminal 14 function selection ) is set as if but … Read more

WINNER INVERTER,S UP / DOWN COMMAND SETTING 10, 11.

It is the function to control the inverter,s output frequency through the control terminal,s on/off . when using this function please make sure to set the 2 multi function input up/down command .if only to set single multi function input the fault ope 03 will occur .besides in the occasion where acceleration /deceleration stop was … Read more

winner inverter fault setting

In the occasion where up/down was set multi step peed command 1~8 will be all non effective . the dwell output frequency when up/down is on will be memorized by the value of d4-01 (dwelling function option of frequency command) the setting value is 1 . the value will be recorded after the power is … Read more