INVERTER,S SETTING VALUE FUNCTION,S

Setting value.== function  .
15 = emergency stop  (a connector : decelerate to stop according to c1-09 when it is on) .
16= motor switch command (motor to selection ) .
17= emergency stop (b connector : decelerate to stop according to c1-09 when it is off) .
18= timing function input ( set by b4-01,02 together with timing output function) .
19= pid control is cancelled (on: pid control is disabled) .
1b= constant write is permitted (on : constant can be input , off: the constant except frequency display can not be input ).
1c= + speed command (on : the summation of d4-02 frequency and analog frequency command .
1d= – speed command ( on : the difference between the frequency of d4-02 and analog frequency command ) .
1e= analog frequency command,s sampling and dwelling .
1f=  frequency command selection terminal 13/14 ( on: select terminal 14 ) enabled only when h3-09 =1f .
20~2f = external exception (it can be set freely ) input method : the detection method of connector a/connector b: normal time / operation stop method : deceleration to stop /coast to stop/emergency stop/ continue to operate .
30= pid control integration reset (in pid control , it is reset when stop command is input or when the inverter is in stop ).
31= pid control integration dwells (on : integration dwells).
60= dc current braking   command (on: dc braking command ).
61= dc braking command 1:maximum output frequency (on: speed research ).
62= dc braking command 2: maximum output frequency (on : speed research ).
63= energy-saving command (on: set energy -saving control by b8-01,2) .
64= external research command 3 .
65= KEB (deceleration at momentary power loss) command  (contact b) .
66= KEB (deceleration at momentary power loss ) command  (contactor a) .
71= speed/torque control switch over (on: torque control ) .
72= zero-servo command (on: zero – servo ) .
73= speed control (asr) proportional gain switch over  (on: c5-03 ).

inverter dc to ac

The value in factory setting 0, it denotes the initial value of 3-line system .
The following listed is the setting for commonly – used function and the reference sections.

functions === =============================== setting value .

3 line system (forward/reverse command ============ 0
multi speed command 1-3/jog frequency selection======3-6
deceleration time selection 1.2 ====================7,1a
emergency stop ============================== 15
fjog command / r jog command ===================12,13
select frequency command terminal 13/14 ============1f
timing function input ===========================18
energy – saving command ========================63