TORQUE CONVERTER / INVERTER. use for control starting load when this function is used the start torque converter compensation is set by command mechanical friction load , for the elevator.the setting of torque converter start torque rising time is in unit of Mr s(note )filter delay is disabled when the setting is between 0~4 ms NOTE: […]
electric inverter frequency reference when the multi function inputs jog frequency reference selection f jog command and r jog command are on.the electric inverter frequency reference default value and set value will change when 0 1-0 3 is changed, for example if preset reference 1 is set to 6.00 Hz and 01-03 is changed […]
motor system in inverter MOTOR 2 LINE TO LINE RESISTANCE . To set the motor,s line to line resistance in unit of ohm . note: the factory setting depends on the capacity of the inverter . please set the motor,s line to line resistance u v v – w w u normally you need to […]
TO CANCEL PID CONTROL off = pid control is enabled . on = pid control is disabled ( normal control of inverter ) with this setting ,the multi – function input switches between pid control and normal inverter control . this function can be used to perform trial operation or jog operation with normal inverter […]
EXTERIOR FAULT ,(SETTING,20-2 F) This is to set how to output the warning to exterior when the exterior equipment is at fault or in a abnormal status and the inverter stops. as the input condition for exterior fault , it can choose the inverter,s action when the exterior is input . the following setting […]
SOLAR MAX INVERTER,S SPECIFICATIONS model 1.2K 2.4K Input voltage 230 VAC Voltage range 170-280 VAC(narrow mode) 90-280vac(wide mode) OUTPUT Voltage regulation (BATT.MODE) +/-10% Transfer time 20 ms typical Wave form Simulated since wave BATTERY Battery voltage 12vdc 24vdc Floating charge voltage 13.5vdc+_0.5 VDC 27.0vdc+_0.5vdc Maximum […]
Terminal s/n Content Specification Ta 1 1 Power supply for encoder Dc + 12v (+-5)max .20ma 2 Dc o v ( grounding terminal for power supply) 3 A phase pulse input terminal H : +8v ~12v L:>+ 1v (max, response frequency 30 Hz) 4 A phase pulse input terminal 5 B phase input terminal […]
NOTE : Before installation please inspect the unit be sure that nothing inside the package is damaged. Installation note before installation,please inspect the unit. be sure that nothing inside the package is damaged. Mountain the unit The unit only can be mounted vertically to a wall surface. please follow below steps: 1. Turn off […]
Signal level selection of multi function analogy terminal 14 0: 0~+ 10 volt please make sure to cut off the over line 1 1: 0 ~+_10 volt please make sure to cut off the over line 1 2: 4 ~ +_20 ma ( 10 bit input ) frequency (current ) it is effective when b1 _ […]
NO Name Description Setting range Factory setting Bias (terminal 14) The command value of each function when 0 v (4 ma)is input , the unit is % -100~ +100 0.0 H3-11 Note : as the adjustment constant of analog input it is classified into 3 types gain deviation ( to be set individually for […]