winner dc braking command

Maximum output frequency / exterior search command 1 (setting , 61 ). off = normal action . on = start speed search from maximum output frequency . Setting frequency / exterior search command 2 (setting , 62) . off = normal action . on = start speed search  from the et frequency ( the command … Read more

winner inverter constant function

h2-01,multi function input (terminal 9-10 ) is multi function contact output terminal 9-10,s function selection (contact ). h2-02,multi function input (terminal 25-27) is the function selection of multi function output 1 terminal 25 (open  circuit collector) . h2-03 multi function input (terminal 26-27) is the function selection of multi function output 2 terminal 26 function … Read more

solar max inverter

SOLAR MAX INVERTER,S SPECIFICATIONS model                                                1.2K 2.4K Input voltage                                                             230 VAC Voltage  range                          170-280 VAC(narrow mode)                              90-280vac(wide mode) OUTPUT Voltage regulation (BATT.MODE)                         +/-10% Transfer time                                         20 ms typical Wave form                                       Simulated since wave BATTERY Battery voltage                           12vdc                       24vdc Floating charge voltage                13.5vdc+_0.5 VDC 27.0vdc+_0.5vdc Maximum … Read more

winner frequency selection

  Terminal s/n Content Specification Ta 1 1 Power supply for  encoder Dc + 12v (+-5)max .20ma 2 Dc o v ( grounding terminal for power supply) 3 A phase pulse input terminal H : +8v ~12v L:>+ 1v (max, response  frequency 30 Hz) 4 A phase pulse input terminal 5 B phase input terminal … Read more

solar inverter bellco

  NOTE : Before installation  please inspect  the unit  be sure that nothing inside the package is damaged. Installation note before installation,please inspect the unit. be sure that nothing inside the package is damaged. Mountain the unit The unit only can be mounted vertically to a wall surface. please follow below steps: 1. Turn off … Read more

winner inverter

Signal level selection of multi function analogy terminal  14 0: 0~+ 10 volt please make sure to cut off the over line 1 1: 0 ~+_10 volt please make sure to cut off the over line 1 2: 4 ~ +_20 ma  ( 10 bit input ) frequency (current ) it is effective when b1 _ … Read more

440 VOLT INVERTER,S (H3-01,11,12) CONSTANT FUNCTIONS

NO Name                         Description Setting range Factory setting Bias (terminal 14) The command value of each function when 0 v (4 ma)is input , the unit is % -100~ +100 0.0 H3-11 Note : as the adjustment constant of analog input it is classified into 3 types gain deviation ( to be set individually for … Read more

solar max inverter dc to ac

SOLAR MAX DC TO AC SOLAR INVERTER,S INSTALLATION AND HOW TO 24 DC VOLT WIRING NOTE: before installation please inspect the unit  be sure that nothing inside the package is damaged. MOUNTING THE UNIT . The unit only can be mounted vertically to a wall surface. please follow below steps, 1. turn off the unit … Read more

440 volt inverter terminals table

    440 VOLT INVERTER,S TERMINALS TABLE No Name Description Setting range Factory setting Change During Option Control methods v/f v/f with pg Open loop vector Flux vector H4-03 Bias (terminal 21) To set the voltage level deviation of multi function analog value output 1 and make the output characteristic to be parallel to the … Read more

440 volt inverter analog signal level setting table

  No Name description Setting range Factory setting Change during operation Control methods v/f v/f with pg Open loop vector Flux vector H4-07 Analog output signal level selection The set signal output level of multi function analog value 1.2 (terminal 21,23)0:0~+10v 1:0~+_10v output note of setting : this signal level setting is suitable for multi … Read more