How To Make a 24V Tesla energy coil at home

How to Make a Tesla Energy Coil at Home   The process How To Make a 24V Tesla energy coil at home is relatively simple, and the components are easily available from your local home improvement store. The only difficult part is choosing the right coil form. You will need a material that can withstand … Read more

440 volt inverter voltage limit

inverter setting values. 440 volt inverter OUTPUT VOLTAGE LIMIT OPTIONS OF 440 VOLT INVERTER. 0: DISABLED. 1:EFFECTIVE THE MOTORS FLUX FALLS AUTOMATICALLY  WHEN THE OUTPUT VOLTAGES REACHES SATURATION STATUS. INVERTER/MOTOR CURRENT. NOTE:  OUTPUT VOLTAGE LIMIT ACTION IS DISABLED , IF THE OUTPUT VOLTAGE REACHES SATURATION STATUS, THE OUTPUT CURRENT HAS NO CHANGE BUT THE TORQUE … Read more

torque converter

TORQUE CONVERTER / INVERTER. use for control starting load when this function is used the start torque converter compensation is set by command mechanical friction load , for the elevator.the setting of torque converter start torque rising time is in unit of Mr s(note )filter delay is disabled when the setting is between 0~4 ms NOTE: … Read more

electric inverter carrier frequency

  CARRIER FREQUENCY set the upper limit and lower limit in K Hz units . the carrier frequency gain is set as follows . frequency is fixed  parameters at electric inverter  c 6-0 1 c 6-0 1>10.0 k=3 10.0>c 6-0 1>5.0:k=2 5.0>c 6-0 1:k=1 NOTE: in vector control , the carrier frequency is set by … Read more

electric inverter afr gain and frequency

  ELECTRIC INVERTER carrier frequency is 2 k Hz . 1:carrier frequency is the setting of c 6-0 1. 2: carrier frequency is 5 k Hz  electric inverter  carrier frequency of the inverter of 400 v is 2.5  Hz ) 185 ~ 300 kw .normally electric inverter is not necessary to change this setting , fine … Read more

electric inverter frequency

  electric inverter frequency reference when the multi function inputs jog frequency reference selection f jog command and r jog command are on.the electric inverter frequency reference default value and set value will change when 0 1-0 3 is changed, for example if preset reference 1 is set to 6.00 Hz and 01-03 is changed … Read more

electric inverter torque reference

TORQUE REFERENCE DELAY TIME . the primary delay time constant of  torque command filter is set in unit of    m r s to adjust the electric inverter torque reference  time constant of the primary delay filmier . to adjust the noise of the torque control signal or the responsive nests with the host controller … Read more

frequency speed and voltage of inverter

  set only  to fine adjust v/f for the output range when using flux vector control of frequency speed and voltage of inverter .normally this setting range and factory setting will be cut by 50%  for the inverter of 200v class . to set the constant e 1-0 4 ~e 1-10 when e 1-0 3 =”f” … Read more

motor system

motor system in inverter MOTOR 2 LINE TO LINE RESISTANCE . To set the motor,s line to line resistance in unit of ohm . note: the factory setting depends on the capacity of the inverter . please set the motor,s line to line resistance u v v – w w u  normally you need to … Read more

winner pid control and operate motor

TO CANCEL PID CONTROL off = pid control is enabled . on = pid control is disabled ( normal control of inverter ) with this setting ,the multi – function input switches between pid control and normal inverter control . this function can be used to perform trial operation or jog operation with normal inverter … Read more