torque converter

TORQUE CONVERTER / INVERTER. use for control starting load when this function is used the start torque converter compensation is set by command mechanical friction load , for the elevator.the setting of torque converter start torque rising time is in unit of Mr s(note )filter delay is disabled when the setting is between 0~4 ms NOTE: … Read more

electric inverter carrier frequency

  CARRIER FREQUENCY set the upper limit and lower limit in K Hz units . the carrier frequency gain is set as follows . frequency is fixed  parameters at electric inverter  c 6-0 1 c 6-0 1>10.0 k=3 10.0>c 6-0 1>5.0:k=2 5.0>c 6-0 1:k=1 NOTE: in vector control , the carrier frequency is set by … Read more

electric inverter frequency

  electric inverter frequency reference when the multi function inputs jog frequency reference selection f jog command and r jog command are on.the electric inverter frequency reference default value and set value will change when 0 1-0 3 is changed, for example if preset reference 1 is set to 6.00 Hz and 01-03 is changed … Read more

electric inverter torque reference

TORQUE REFERENCE DELAY TIME . the primary delay time constant of  torque command filter is set in unit of    m r s to adjust the electric inverter torque reference  time constant of the primary delay filmier . to adjust the noise of the torque control signal or the responsive nests with the host controller … Read more

motor system

motor system in inverter MOTOR 2 LINE TO LINE RESISTANCE . To set the motor,s line to line resistance in unit of ohm . note: the factory setting depends on the capacity of the inverter . please set the motor,s line to line resistance u v v – w w u  normally you need to … Read more

WINNER,S OPERATION SELECTION AT OVER SPEED

OPERATION SELECTION AT OVER SPEED/ DEVIATION . winner inverter set the stop method when over speed occurs.0:deceleration to stop using deceleration time 1 (c 1-0 2). 1: coast to stop. 2: emergency stops using the emergency stop time ( c 1-0 9). 3:continue operation it dose not need to be set normally to protect the … Read more

inverter speed value

inverter speed value . In the realm of modern technology, the concept of “inverter speed value” has emerged as a pivotal factor in the efficient operation of various electronic devices and systems. As we delve into this intricate subject, we aim to provide an in-depth, comprehensive understanding of this crucial component, its functionality, and its … Read more

digital systems

    DIGITAL SYSTEMS INPUT OPTION OF INVERTER. To set the input method of digital command card . 0: bcd . 1% 1: bcdo . 1% 2: bcdo. 01% unit 3: bcd 1Hz unit. 4:bcdo . 1 Hz unit 5:bcdo. 1Hz unit . 6: bcd special setting (5-digital input) . 7: binary system. note: when … Read more

3 phase inverter

3 PHASE INVERTER OUTPUT MODE SELECTION . Set the 3 phase inverter  output  mode  in the following constants when using a d0-08 digital output card 0: – channel individual outputs  code output ( binary system code) . note: the item output by d0-08 according to f6-01 setting , please set the code output as follows. … Read more

working of inverter

FUNCTION TABLE OF MULTI FUNCTION  INPUT (H1). 0: 3 line system program control (forward / reverse command ). 1: local / remote selection (on operator off parameter setting). 2: selection / inverter selection (on is optional ). 3: when h3 – 05 ( multi functional multi speed command 1 analog input function selection ) is … Read more