Battery Backup Time Calculator
Find out how long a battery can power your appliances. Enter your battery voltage, Ah capacity, appliance load, inverter efficiency, and usable capacity below, and the calculator will estimate your backup time instantly — in hours, and in a plain hours-and-minutes format that's easy to plan around.
Calculate Your Battery Backup Time
Fill in the fields below. Defaults are pre-filled with a typical home inverter setup so you can see how the calculator works before entering your own numbers.
Advanced settings (battery efficiency, quantity, appliance list)
Optional: Build Your Load From Appliances
Add appliances below and the total will automatically fill the Load Power field above.
| Appliance | Qty | Watts each | Hours used |
|---|
Results are estimates based on the values entered. Actual battery runtime can vary due to battery chemistry, age, temperature, discharge rate, inverter efficiency, load characteristics, wiring losses, and manufacturer specifications. For critical installations, use manufacturer runtime curves and professional electrical guidance.
How to Use the Calculator
Using the calculator takes five steps, and you'll see the result update the moment you click Calculate:
- Enter battery voltage. Choose a common preset (12V, 24V, 36V, 48V) from the dropdown, or select "Custom voltage" and type in your own if your system doesn't match those — the custom field appears automatically.
- Enter battery capacity in Ah. This is printed on the battery's label or datasheet, for example "100Ah."
- Enter your load in watts. This can be a single appliance or your total connected load. If you're not sure of the total, open "Advanced settings" and use the appliance list — enter each item's quantity, wattage, and hours of use, click "Add Appliance" for more rows, then click "Use Appliance Total as Load" to fill the Load Power field automatically.
- Adjust inverter efficiency and usable capacity. Drag the efficiency slider or pick a usable-capacity percentage; the defaults (90% inverter efficiency, 80% usable capacity) reflect common real-world settings, but adjust them if you have better figures from your equipment's datasheet. For lithium batteries, a battery efficiency field and a "number of batteries" field for parallel banks are also available under Advanced settings.
- Click "Calculate Backup Time." The result panel shows estimated backup time in hours and in a plain "X hours Y minutes" format, plus the nominal battery energy, usable energy, usable AC energy, and estimated battery current. Use "Copy Result" to grab the headline figure, or "Reset" to return every field to its default.
If you enter a load of 0 watts, the field is flagged and the calculator won't return a result — backup time isn't a meaningful figure without something actually consuming power. The same inline validation applies to voltage, Ah, inverter efficiency, and usable capacity: each must be greater than zero, and the two percentage fields must fall between 1% and 100%.
Quick Battery Backup Formula
Convert percentages to decimals before using the formula: 80% becomes 0.80, and 90% becomes 0.90. This is the same calculation the tool above performs automatically, so you can also do it by hand for a quick sanity check.
Worked Example
Battery: 12V 100Ah | Usable capacity: 80% | Inverter efficiency: 90% | Load: 300W
12 × 100 × 0.80 × 0.90 = 864 Wh available to the load.
864 ÷ 300 = 2.88 hours — about 2 hours 53 minutes.
Introduction
When the power goes out, the question everyone asks is the same one: how long will the battery last? A battery backup time calculator answers that question by turning a handful of numbers — battery voltage, amp-hour (Ah) capacity, the wattage of what you're running, and the efficiency of the equipment in between — into a single, practical estimate: hours and minutes of runtime.
This matters whether you're sizing a battery for a new inverter system, checking whether your existing setup can survive a multi-hour outage, or simply trying to decide whether to run the refrigerator or the air conditioner first. Getting the estimate right starts with understanding what each input actually represents. Battery voltage and Ah capacity together define how much energy a battery nominally holds. Usable capacity (depth of discharge) accounts for the portion of that energy you should realistically draw. Inverter efficiency accounts for the energy lost converting DC battery power into the AC power your appliances use. And load, in watts, is what determines how quickly that energy gets used up.
The calculator above does this math for you the moment you enter your numbers. The sections below explain where each formula comes from, work through real examples at 12V, 24V, and 48V, and cover the practical factors — battery age, temperature, discharge rate, and battery chemistry among them — that explain why a battery's real-world runtime is rarely identical to the theoretical number. Treat the result as a solid planning estimate, then confirm anything safety-critical against your battery manufacturer's specifications.
Battery Backup Time Formula
The calculation happens in four steps, each building on the last.
Step 1: Nominal Battery Energy
This gives the battery's rated energy content in watt-hours — the standard unit for comparing how much energy different batteries can store, regardless of their voltage.
Step 2: Usable Battery Energy
Not all of a battery's rated energy should be drawn out in normal use. The usable capacity, or depth of discharge, scales the nominal energy down to a realistic, sustainable figure.
Step 3: Usable AC Energy
The inverter converts DC battery power into AC power, and that conversion isn't lossless. Multiplying by inverter efficiency (as a decimal, e.g., 0.90 for 90%) accounts for that loss.
Step 4: Backup Time
Dividing the usable AC energy by the load in watts gives backup time in hours. If battery (round-trip)
efficiency is also a factor — relevant mainly for some lithium systems with a battery management
system, or where the manufacturer publishes a specific efficiency figure — multiply it into Step 3
alongside inverter efficiency: V × Ah × DoD × Inverter Efficiency × Battery Efficiency.
Understanding Battery Capacity
How Battery Voltage and Ah Determine Energy
Voltage and Ah together, not either one alone, determine how much energy a battery holds. A 12V 100Ah battery has a nominal energy rating of 12 × 100 = 1,200 Wh. A 24V 100Ah battery holds 24 × 100 = 2,400 Wh — twice as much, even though the Ah figure is identical, because the voltage is doubled. A 48V 100Ah battery holds 48 × 100 = 4,800 Wh.
This is why comparing batteries by Ah alone is misleading unless the voltage is also the same. A 12V 200Ah battery (2,400 Wh) and a 24V 100Ah battery (2,400 Wh) store approximately the same amount of energy, despite the Ah numbers looking very different.
What Does Battery Ah Mean?
Ampere-hours describe how much current a battery can theoretically supply over a set period under specific test conditions — commonly a 20-hour or 100-hour discharge rate, depending on the manufacturer and chemistry. A "100Ah" rating does not mean the battery will always supply exactly 100 amps for one hour, or 5 amps for 20 hours, under every condition. Draw current faster than the rated test condition and the usable capacity typically drops; draw it more slowly and it may hold up closer to, or occasionally slightly above, the rated figure. This is one reason the calculator's output is described as an estimate rather than a guarantee — the simple V × Ah math assumes ideal, rated-condition behavior.
Understanding Appliance Load
How Appliance Wattage Affects Battery Backup
Load and backup time are inversely related: a higher-wattage load drains the same battery faster, and a lower-wattage load stretches it further. In very general terms, LED lighting and small electronics sit at the low end of typical household loads; fans, televisions, and routers sit in the moderate range; refrigerators draw variable power because their compressor cycles on and off; and air conditioners, electric heaters, microwaves, and water pumps sit at the high end, with pumps and compressors also drawing a brief starting surge above their running wattage. These are general patterns, not universal numbers — check the rating label or datasheet for your specific appliance model.
Building a Total Load From Multiple Appliances
The advanced section of the calculator above lets you add appliances one row at a time, each with a quantity, a wattage, and expected hours of use, and it totals the wattage for you. As a manual example:
| Appliance | Quantity | Watts each | Subtotal |
|---|---|---|---|
| LED bulbs | 5 | 10 W | 50 W |
| Fan | 2 | 60 W | 120 W |
| TV | 1 | 100 W | 100 W |
| Router | 1 | 15 W | 15 W |
Total load: 50 + 120 + 100 + 15 = 285 W. That figure can then be entered directly into the Load Power field to calculate backup time for this combination.
Inverter Efficiency
How Inverter Efficiency Affects Battery Backup
An inverter converts the battery's DC power into the AC power that most household appliances use, and that conversion always involves some loss, typically dissipated as heat. If a battery supplies 1,000 W of DC power and the inverter is 90% efficient, the connected AC appliances receive roughly 900 W of usable power — the remaining 100 W is lost in conversion, not delivered to the load. Because that lost energy still has to come from the battery, lower inverter efficiency directly reduces backup time for a given AC load.
Typical inverter efficiency ranges from roughly 80% at the low end to around 95% for high-quality units running near their optimal load point. Efficiency also isn't constant: it usually dips at very light loads and very heavy loads, and peaks somewhere in the middle of the inverter's rated capacity. If your inverter's datasheet publishes an efficiency curve, use the figure closest to your actual operating load for the most accurate estimate.
Depth of Discharge
What Is Depth of Discharge?
Depth of discharge (DoD) is the percentage of a battery's rated capacity you plan to draw out before recharging, and usable capacity is simply the complementary way of expressing the same idea. A 100Ah battery used at 50% usable capacity effectively delivers 100 × 0.50 = 50Ah of usable capacity per cycle; at 80% usable capacity, it delivers 100 × 0.80 = 80Ah.
The appropriate usable capacity for your system depends heavily on battery chemistry and the manufacturer's own guidance. Some chemistries and duty cycles tolerate deeper discharge with less long-term capacity loss than others, and manufacturers typically publish recommended discharge limits, cycle-life-versus-DoD charts, or warranty terms tied to a specific discharge range.
Battery Type and Runtime
Lead-Acid vs Lithium Battery Backup Time
Battery chemistry affects both usable capacity and how gracefully a battery handles heavy loads.
Lead-acid batteries (including flooded, AGM, and gel variants) remain common in traditional home inverter systems. Their usable capacity is sensitive to discharge rate — drawing power quickly tends to reduce the effective Ah available compared with a slow, steady draw — and their terminal voltage changes noticeably as they discharge. They are also comparatively heavy for their energy content, and manufacturers typically specify a maximum recommended depth of discharge to protect cycle life.
Lithium batteries (commonly lithium iron phosphate in stationary backup applications) generally deliver a higher proportion of their rated capacity as genuinely usable energy across a wider range of discharge rates, and are lighter for the same energy content. Most include a battery management system that actively monitors and, in some cases, limits charging and discharging to protect the cells. Actual usable energy and recommended discharge limits still depend on the specific manufacturer's specifications, so treat any general comparison as a starting point rather than a substitute for the datasheet.
What Is the Peukert Effect?
Lead-acid batteries in particular can deliver measurably less usable capacity when discharged at high current than their rated Ah figure suggests, an effect commonly described using Peukert's equation. In practical terms: a simple V × Ah ÷ W calculation, done without any adjustment, can overestimate real-world runtime for lead-acid batteries under heavy load, because it assumes the battery performs identically regardless of how fast it's discharged. This page keeps the core calculator formula simple and beginner friendly, and instead accounts for real-world variance through the usable capacity (DoD) input — using a more conservative usable capacity percentage for heavy, fast-discharge loads is a practical way to build in some margin for this effect without needing to work through Peukert's equation by hand.
Series and Parallel Batteries
Series Batteries
Connecting identical batteries in series increases total voltage while the Ah rating stays the same as a single battery. Two 12V 100Ah batteries wired in series produce a 24V 100Ah bank, with nominal energy of 24 × 100 = 2,400 Wh.
Parallel Batteries
Connecting identical batteries in parallel keeps voltage the same while Ah capacity adds up. Two 12V 100Ah batteries wired in parallel produce a 12V 200Ah bank, also with nominal energy of 12 × 200 = 2,400 Wh — the same total energy as the series example above, arrived at a different way.
Series-Parallel Systems
Larger systems often combine both. Four 12V 100Ah batteries arranged as two parallel pairs, each pair wired in series with the other (a "2S2P" configuration), produce a 24V 200Ah bank with nominal energy of 24 × 200 = 4,800 Wh. Always follow the battery manufacturer's guidance and proper electrical practice when wiring batteries in series or parallel — mixing battery ages, states of charge, or capacities in the same bank can cause imbalance and premature failure.
Practical Calculation Examples
Example 1: 12V 100Ah Battery
Battery: 12V, 100Ah | Load: 300W | Inverter efficiency: 90% | Usable capacity: 80%
864 ÷ 300 = 2.88 hours ≈ 2 hours 53 minutes
Example 2: 24V 200Ah Battery
Battery: 24V, 200Ah | Load: 500W | Inverter efficiency: 90% | Usable capacity: 80%
3,456 ÷ 500 = 6.91 hours ≈ 6 hours 55 minutes
Example 3: 48V Battery System and Current at Different Voltages
Higher battery voltage reduces the current needed to deliver the same power, which is one reason larger systems often move to 24V or 48V rather than staying at 12V. For a 1,000W load, approximate DC current before accounting for inverter efficiency works out as follows:
| System Voltage | Approx. Current for 1,000 W |
|---|---|
| 12 V | 1000 ÷ 12 ≈ 83.3 A |
| 24 V | 1000 ÷ 24 ≈ 41.7 A |
| 48 V | 1000 ÷ 48 ≈ 20.8 A |
Lower current at higher voltage generally means thinner cabling and lower resistive losses for the same power delivery, though actual current also depends on inverter efficiency (see the battery current formula below).
Estimating Battery Current
Example: a 500W load on a 24V battery through a 90%-efficient inverter draws approximately 500 ÷ (24 × 0.90) ≈ 23.15 A from the battery. This figure is useful for checking cable sizing and fuse ratings against your wiring specifications.
Battery Backup Time for Common Home Appliances
The list below illustrates roughly where common appliances tend to fall in terms of power draw, so you can get a rough feel for backup time before entering exact numbers. Actual wattage varies significantly by model, age, and setting, so always check the rating label or the appliance's own specification sheet for a real calculation.
- LED lights — generally low, often single-digit to low double-digit watts per bulb.
- Ceiling or pedestal fan — typically low-to-moderate, varying with speed setting.
- Wi-Fi router — generally low and fairly constant.
- Television — moderate, varying with screen size and technology.
- Laptop — generally low while running, higher briefly while charging.
- Desktop computer — moderate, varying widely by hardware.
- Refrigerator — variable; the compressor cycles on and off, so average draw is lower than peak running draw, and starting current briefly spikes higher still.
- Water pump — variable to high, often with a notable starting surge.
- Microwave — high while cooking.
- Air conditioner — high, with a starting surge above running wattage.
For an accurate backup-time estimate, use the wattage printed on each appliance's rating label, or its running wattage from the manufacturer's specification sheet, rather than the general ranges above.
Why Is My Actual Battery Backup Time Different?
The calculator gives a planning estimate built on ideal, rated-condition assumptions. Real installations diverge from that estimate for several reasons:
- Battery age — usable capacity declines gradually as a battery goes through charge/discharge cycles.
- Battery temperature — capacity and performance are typically rated at a specific reference temperature; operating outside that range can change available capacity.
- Battery health — damaged cells, sulfation (lead-acid), or cell imbalance can reduce usable capacity below the rated figure.
- Actual appliance load — real appliances rarely draw a perfectly flat wattage; compressors, motors, and electronics cycle and fluctuate.
- Inverter efficiency — efficiency varies with load level and isn't a single fixed number in practice.
- Standby consumption — the inverter itself draws some power even with a light load connected.
- Discharge rate and the Peukert effect — especially relevant to lead-acid batteries under heavy load, as discussed above.
- Power factor — some AC loads draw more apparent power than their real (working) power rating suggests.
- Wiring losses — resistance in cables and connections dissipates a small amount of energy as heat.
- State of charge at the start — a battery that starts an outage partially discharged has less usable energy available than a fully charged one.
- Manufacturer-rated capacity conditions — the Ah rating on the label is usually measured under specific test conditions that may not match your actual discharge rate.
- Cutoff voltage — inverters and battery management systems disconnect the load at a minimum voltage to protect the battery, which effectively caps usable capacity.
- Battery chemistry — different chemistries respond differently to all of the above factors.
Treat the calculator's output as a solid estimate for planning, not a guarantee, and build in a reasonable margin for anything safety-critical.
Power Factor and AC Loads
For AC loads, real power (watts) and apparent power (volt-amps) aren't always identical. In general, for single-phase AC: Power (W) = Voltage × Current × Power Factor. Purely resistive loads like incandescent heaters have a power factor close to 1, while motors, pumps, refrigerators, and other inductive loads often have a lower power factor, meaning their apparent power draw is somewhat higher than their real power rating alone would suggest. This mainly affects how you size an inverter and wiring; for the backup-time calculation itself, use the appliance's rated real power (watts) as the load figure.
Starting Surge and Battery Backup
Some appliances — refrigerators, water pumps, compressors, air conditioners, and certain power tools among them — briefly draw significantly more power at startup than during normal running. This surge mainly affects how large an inverter needs to be and the instantaneous current the battery must supply for a short period; it can also interact with practical system behavior, for example if repeated starts occur during an outage. Size your inverter for the starting surge of your largest motor-driven load, not just its running wattage, and use the running wattage for the backup-time calculation itself.
How to Increase Battery Backup Time
A handful of practical adjustments can meaningfully extend real-world backup time:
- Reduce unnecessary loads during an outage — turn off equipment you don't immediately need.
- Switch to efficient LED lighting where you haven't already.
- Reduce standby/idle consumption from devices left plugged in.
- Choose energy-efficient appliance models where practical.
- Increase total battery capacity (more Ah, or an additional battery in parallel).
- Use an appropriate battery voltage for your system size, reducing current and associated losses.
- Maintain battery health — proper charging, avoiding excessive discharge, and following the manufacturer's maintenance guidance.
- Keep terminals and connections clean and properly torqued to minimize resistive losses.
- Match your inverter size to your typical load so it runs nearer its efficiency sweet spot.
- Prioritize which high-power appliances actually need to run during an outage.
How Much Battery Capacity Do I Need?
Sizing a battery for a target backup time works in the reverse direction of the main calculator:
- Determine your total load in watts.
- Decide how many hours of backup you need.
- Choose a battery voltage appropriate for your system.
- Account for inverter efficiency.
- Account for usable battery capacity (depth of discharge).
- Add a reasonable design margin above the theoretical minimum.
- Check the result against real, available battery sizes and confirm compatibility with your inverter and charge controller.
Reverse Calculation Example
Target: 500W load for 4 hours, on a 24V system, 80% usable capacity, 90% inverter efficiency.
Required Ah = 2,000 ÷ 17.28
Required Ah ≈ 115.7 Ah
In practice you'd compare this against commonly available battery sizes (for example, a 120Ah or 150Ah battery) and manufacturer specifications, then add margin for aging and real-world losses.
Common Battery Backup Calculation Mistakes
- Comparing batteries by Ah alone without accounting for voltage — a 12V 200Ah battery and a 24V 100Ah battery store roughly the same energy.
- Ignoring inverter efficiency, which overstates usable energy and backup time.
- Assuming 100% depth of discharge is always appropriate, without checking the battery's recommended limits.
- Using appliance apparent power (VA) instead of real power (W) for inductive loads, which can overstate the effective load.
- Forgetting starting surge when sizing the inverter, even though it isn't part of the backup-time calculation itself.
- Treating the calculated result as guaranteed rather than an estimate that should include a margin.
- Not accounting for battery age or temperature, both of which reduce usable capacity below the nameplate rating over time.
Battery Backup Time Table
Example scenario: 12V, 100Ah battery, 80% usable capacity, 90% inverter efficiency (usable AC energy: 864 Wh).
| Load | Estimated Backup Time |
|---|---|
| 100 W | 8.64 hours (≈ 8 h 38 min) |
| 200 W | 4.32 hours (≈ 4 h 19 min) |
| 300 W | 2.88 hours (≈ 2 h 53 min) |
| 500 W | 1.73 hours (≈ 1 h 44 min) |
| 750 W | 1.15 hours (≈ 1 h 9 min) |
| 1,000 W | 0.86 hours (≈ 52 min) |
Note: actual runtime varies with battery condition, temperature, discharge rate, and other factors discussed above.
Battery Capacity Comparison Table
Nominal energy values, before efficiency and usable-capacity adjustments:
| Battery | Nominal Energy |
|---|---|
| 12V 50Ah | 600 Wh |
| 12V 100Ah | 1,200 Wh |
| 12V 150Ah | 1,800 Wh |
| 12V 200Ah | 2,400 Wh |
| 24V 100Ah | 2,400 Wh |
| 24V 200Ah | 4,800 Wh |
| 48V 100Ah | 4,800 Wh |
Battery Capacity vs Usable Energy
It helps to think of a battery's energy in four stages, each one smaller than the last:
- Rated (nominal) battery energy — Voltage × Ah, the label figure.
- Usable energy — after applying depth-of-discharge / usable capacity limits.
- Energy after inverter losses — after applying inverter efficiency.
- Energy actually delivered to appliances — what's left after real-world wiring and load variation.
Each stage subtracts a bit more from the theoretical maximum, which is exactly why a naive V × Ah ÷ W calculation, with no adjustment for any of these stages, tends to overstate real backup time.
Design Margin
It's generally not advisable to design a battery system to run exactly at its theoretical calculated limit. Battery aging, unexpected additional load, temperature swings, and gradual efficiency changes over the life of the equipment all eat into the margin between the theoretical estimate and what the system can reliably deliver years down the line. Rather than one fixed universal percentage, build in a margin appropriate to how critical the backup is — a larger margin for medical equipment or business-critical systems, a smaller one for convenience loads like lighting.
UPS Battery Backup Time Calculator
The same underlying math applies to UPS (uninterruptible power supply) systems used for computers and sensitive electronics, with the same core inputs: UPS/battery voltage, battery Ah, and UPS efficiency, applied against the connected load. A few UPS-specific factors are worth noting: runtime is often quoted as a percentage of the UPS's rated load rather than in absolute watts, battery age affects UPS runtime just as it does any other battery system, and many UPS manufacturers publish runtime-versus-load charts measured under controlled conditions. Where available, those manufacturer charts can be more accurate for a specific UPS model than a generic formula, since they account for that unit's actual efficiency curve and battery characteristics.
Inverter vs UPS
| Feature | Inverter | UPS |
|---|---|---|
| Backup power | Yes | Yes |
| Typical use | Home / building backup systems | Computers, servers, sensitive electronics |
| Transfer behavior | Depends on system design | Often designed for very fast transfer |
| Runtime | Battery capacity dependent | Battery capacity dependent |
Safety Considerations
Battery systems can deliver very high currents, and a few basic precautions apply to any installation:
- Batteries should be installed according to the manufacturer's instructions.
- Use appropriately rated fuses or circuit breakers for overcurrent protection.
- Follow correct polarity when connecting batteries and equipment.
- Never short-circuit a battery's terminals.
- Use properly rated cables for the expected current.
- Some battery technologies require ventilation — check the manufacturer's guidance.
- For high-power systems, professional installation and inspection may be appropriate.
Frequently Asked Questions
What is a battery backup time calculator?
It's a tool that estimates how long a battery can power a given load, based on the battery's voltage and Ah capacity, the load in watts, inverter efficiency, and the usable portion of the battery's capacity.
How do I calculate battery backup time?
Multiply battery voltage by Ah capacity to get nominal watt-hours, scale that by usable capacity (depth of discharge) and inverter efficiency to get usable AC watt-hours, then divide by the load in watts to get hours of backup.
How long will a 12V 100Ah battery last?
It depends entirely on the load. At 80% usable capacity and 90% inverter efficiency, that battery holds about 864 Wh of usable AC energy — roughly 2.88 hours at a 300W load, or about 8.6 hours at a 100W load. Use the calculator above with your actual load for a precise estimate.
How long will a 24V 100Ah battery last?
A 24V 100Ah battery holds twice the nominal energy of a 12V 100Ah battery (2,400 Wh vs 1,200 Wh), so at the same load, its estimated backup time is roughly double, before efficiency and usable-capacity adjustments are applied identically to both.
How long will a 48V 100Ah battery last?
A 48V 100Ah battery holds 4,800 Wh nominal — four times a 12V 100Ah battery's rating — so for the same load, in the same DoD and inverter-efficiency conditions, its estimated runtime is roughly four times as long.
How many watts can a 100Ah battery provide?
That depends on voltage and how long you want to run it. A 12V 100Ah battery holds 1,200 Wh nominal; at 500W, that's roughly 2.4 hours before efficiency and usable-capacity adjustments. Higher voltage batteries with the same Ah rating hold proportionally more total energy.
Does inverter efficiency affect backup time?
Yes. A less efficient inverter wastes more of the battery's energy as heat during DC-to-AC conversion, which directly reduces the energy available to your appliances and shortens backup time.
Does battery voltage affect runtime?
Voltage affects runtime through its effect on total energy (Wh = V × Ah). For the same Ah rating, a higher-voltage battery holds more total energy and, for the same load, provides longer runtime. Higher voltage also reduces current for a given power level, which can reduce wiring losses.
What does Ah mean on a battery?
Ah (ampere-hours) is a measure of a battery's charge capacity, generally measured under a specific test discharge rate. It doesn't directly state energy (Wh) unless combined with the battery's voltage.
What is battery usable capacity?
Usable capacity is the portion of a battery's rated capacity you plan to draw before recharging — the complement of depth of discharge. It's typically less than 100% of the rated capacity, based on the manufacturer's recommendations for the specific battery chemistry.
What is depth of discharge?
Depth of discharge (DoD) is the percentage of a battery's capacity that has been discharged relative to its full rated capacity. A battery discharged to 20% depth of discharge has 80% usable capacity remaining.
Why is my actual backup time lower than the calculator's estimate?
Likely contributors include battery age, temperature, actual load being higher than assumed, inverter efficiency being lower than assumed at your specific load level, standby consumption, wiring losses, and the battery not starting at a full state of charge.
How does battery age affect runtime?
Usable capacity typically declines gradually as a battery accumulates charge/discharge cycles and calendar age, so an older battery generally delivers less runtime than its original nameplate rating suggests.
How does temperature affect battery performance?
Battery capacity ratings are usually specified at a particular reference temperature. Operating significantly above or below that reference can change the effective usable capacity and, in some chemistries, safe charge/discharge limits — check the manufacturer's temperature guidance.
Can I calculate UPS backup time with this calculator?
Yes — the same voltage, Ah, load, and efficiency inputs apply to UPS systems. For a specific UPS model, also check the manufacturer's published runtime chart if one is available, since it accounts for that unit's real efficiency curve.
How many batteries do I need for 1,000 watts?
That depends on your target backup duration, battery voltage, usable capacity, and inverter efficiency. Use the reverse-calculation formula in the "How Much Battery Capacity Do I Need" section above to work out the required Ah for your target runtime, then compare against available battery and bank configurations.
What is the difference between Ah and Wh?
Ah (ampere-hours) measures charge capacity and doesn't account for voltage. Wh (watt-hours) measures energy and is calculated as voltage × Ah. Comparing batteries by Wh is more meaningful when their voltages differ.
How do I calculate battery capacity for 4 hours of backup?
Use the reverse formula: Required Ah ≈ (Load Watts × 4) ÷ (Battery Voltage × Usable Capacity × Inverter Efficiency). See the worked reverse-calculation example above for a full walkthrough.
Does a refrigerator use the same power all the time?
No. A refrigerator's compressor cycles on and off, so its average power draw over time is lower than its peak running wattage, and it briefly draws a starting surge above its running wattage each time the compressor starts.
Can this calculator calculate lithium battery runtime?
Yes — enter the lithium battery's voltage, Ah rating, and the usable capacity or DoD figure from its datasheet. Lithium batteries often support a higher usable capacity than lead-acid batteries of similar rated Ah, so check the manufacturer's specification for the correct figure to use.
Related Electrical Calculators
Final Conclusion
Battery backup time comes down to a straightforward relationship: how much usable energy your battery holds, divided by how quickly your appliances consume it. Voltage and Ah together set the nominal energy ceiling; usable capacity (depth of discharge) and inverter efficiency scale that down to a realistic figure; and load in watts determines how fast that energy is drawn down. The calculator above walks through exactly that chain of math the moment you enter your numbers.
Real-world runtime will still vary with battery age, temperature, discharge rate, and the specific characteristics of your equipment, which is why the result is best treated as a solid planning estimate rather than an exact guarantee. Use it to size a new battery bank, sanity-check an existing setup, or decide what to run first during an outage — then verify anything safety-critical against your battery and inverter manufacturers' own specifications.
Use the Battery Backup Time Calculator above to estimate your runtime, then explore the related calculators below to size your wiring, generator, solar array, or motor loads more precisely.